16
Ball Valve
(Recommended)
Tee tting for
icemaker
7. Point Y Tank’s input & output connection:
Prepare tank: See Fig.12. Apply 6-8 wraps of Teflon tape to tank’s threaded Output stem on top of
tank (remove rubber cap if there is one). Screw tank Valve onto Output stem.
Tubing color: Yellow tubing. Connect the YELLOW tubing from Stage-5 T-fitting to the tank’s valve.
Fitting type: Quick-Connect fitting on ball valve. Simply push Yellow tubing into valve port.
Air pressure: The 4 gallon tank comes pre charged at 5 psi, 14 gallon tank at 7 psi.
Fig. 12
OFF Position ON Position
Tank Ball Valve
Option: Ice-maker Connection
If you want to connect product water from the RO to your ice-maker, you will need:
One T-fitting, preferably the quick-connect type fitting
Extra ¼ “ tubing long enough to go from the RO system to your ice-maker
Optional: One shut-off valve, preferably the quick-connect type.
See Fig.13. Before connecting the product water line from Point Z to H, add a T-fitting near
point H to divert product water to both the ice-maker and the faucet. It is best open the line to
the ice maker after the first tank has been discarded and the 2nd tank has completely filled.
Standard 4-gallon Tank Diagram:
Refrigerator
Fig. 13